Flint-walling CPJS Shallow Well Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Pumpen Flint-walling CPJS Shallow Well herunter. Flint & Walling CPJS Shallow Well User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
®
Installation Instructions and Parts Manual
“CPJ” SERIES JET PUMPS
Convertible Jet Pumps
1/2 HP “CPJ”
CONVERTIBLE
3/4 - 1-1/2 HP “CPJ”
CONVERTIBLE
1/3 - 1/2 HP “CPJS”
SHALLOW WELL
3/4 - 1-1/2 HP “CPJS”
SHALLOW WELL
Shallow Well Jet Pumps
IL0189
IL0190
IL0192
IL0188
132463 A
TOP
IL0194
IL0195
Top
Top, if used for
shallow well
Shallow Well Ejector for lifts to 25
ft.
Convertible Ejector For Shallow
or Deep well applications (4 inch
inside diameter wells).
Single Pipe Deep Well
Ejector (2 inch inside
diameter wells).
Ejectors (Purchase separately)
For loose, missing or damaged parts, or if the
unit does not seem to be operating properly,
please call before returning unit to the place of
purchase
Phone: 1-800-742-5044
Service Hours:
Monday thru Friday - 7:30 am to 5:00 pm EST
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - 132463 A

®Installation Instructions and Parts Manual “CPJ” SERIES JET PUMPSConvertible Jet Pumps1/2 HP “CPJ” CONVERTIBLE3/4 - 1-1/2 HP “CPJ” CONVERTIBLE1/3 - 1

Seite 2 - SAFETY INFORMATION

10WELL TO PUMP CONNECTION (SUCTION PIPE)4b. For driven wells, a check valve is required at the top of the well to maintain prime. Flow arrow must poi

Seite 3 - GENERAL PUMP INFORMATION

11PUMP TO PRESSURE TANK CONNECTION (DISCHARGE PIPE)Shallow Well Application Only:1. Begin the connection to the pressure tank. Using a 3/4 in. x 3 in

Seite 4

12PUMP TO PRESSURE TANK CONNECTION (DISCHARGE PIPE)Deep Well Application Only:1. To begin the connection to the pressure tank, loosely assemble ow c

Seite 5

13TANK TO HOUSE CONNECTION1. Most pressure tanks will have a 1 inch inlet elbow on the bottom. Connect to this elbow with a 1 in. MPT x 1 in. slip (

Seite 6 - INSTALLING PIPING IN WELL

144. Install a 3/4 in. union (optional) and continue with pipe and 3/4 in. x 3/4 in. x 3/4 in. tee. (Fig. 4)3. Attach a 1 in. slip (glue) x 3/4 in.

Seite 7

15PUMP ELECTRICAL CONNECTIONSIL14012L1L2ABL1L2AB115 VoltsSingle PhaseLine230 VoltsSingle PhaseLineYELLOWWHITEGREYREDTANYELLOWWHITEGREYREDTANCheck Volt

Seite 8

16PUMP ELECTRICAL CONNECTIONS3. Insert an electrical wire strain relief into the opening in the side of the pressure switch closest to the motor. (Fi

Seite 9

177. Insert an electrical wire strain relief into the opening in the opposite side of the pressure switch. (Fig. 7)IL1376Wire from motorPressureSwitc

Seite 10 - Flow Arrow

18PUMP ELECTRICAL CONNECTIONSTo change from 115V to 230V11. The motor of this pump is dual voltage and can run on either 115V or 230V. In general, 23

Seite 11

19PUMP PRIMING & STARTUPShallow Well Application Only: CAUTION: All pumps must be primed (lling the cavity with water) before they are rst ope

Seite 12 - Control

2PRODUCT SPECIFICATIONS SAFETY INFORMATION DANGER: 1. Always disconnect power source before performing any work on or near the motor or its connec

Seite 13

20PUMP PRIMING & STARTUP Deep Well Application Only: CAUTION: All pumps must be primed (lling the cavity with water) before they are rst opera

Seite 14 - Shut off valve

21PUMP PRIMING & STARTUP 5. With pump operating at high pressure, open two or more faucets and slowly unscrew the ow control screw until maximu

Seite 15 - Wiring The Pressure Switch

22Rotary Seal Assembly Replacement CAUTION: Make certain that the power supply is disconnected before attempting to service the unit! The rotary se

Seite 16

23TROUBLESHOOTINGProblem Possible Cause Corrective ActionLittle or no discharge1. Casing not initially lled with water 1. Fill pump casing2. Sucti

Seite 17 - Wire from

24REPAIR PARTSIL0190IL0189IL01913124567810111291315IL018813141616“CPJ” Convertible3/4 to 1-1/2 HP“CPJS” Shallow Well1/3 to 1/2 HP“CPJS” Shallow Well3/

Seite 18 - ES05S Rev: B

3Typical Pump SetupConvertible jet pumps are designed for use in these applications:1. Shallow wells (0 - 25 ft. lift) where ejector bolts to pump (Fi

Seite 19 - Air relief plug

4GENERAL PUMP INFORMATIONIL02093/4 or 1 in. Discharge PipeSuctionPipe SeeTable BDischarge to Home Pipe SupportFoot Valve2 in. ID Well33. Deep wells w

Seite 20 - Deep Well Application Only:

5VentilationVentilation and drainage must be provided to prevent damage to the motor from heat and moisture.FreezingThe pump and all piping must be pr

Seite 21

6Tools requiredPREPARATIONPipe wrenches (2)Wire strippersNeedle-nose pliersPhillips screwdriverWire cuttersAdjustable wrenchPipe tapePipe dopeNOTE: Fo

Seite 22 - CARE AND MAINTENANCE

7INSTALLING PIPING IN WELL IL11883/4 or 1 in. Discharge Pipe1-1/4 in.SuctionPipeDischarge to Home CheckValve2RECOMMENDED SUCTION PIPE SIZES FOR SHALLO

Seite 23 - TROUBLESHOOTING

8Deep Well (Single Pipe System)Application - Where pumping water level is greater than 25 feet and inside diameter of well is 2, 2-1/2 or 3 inches. (F

Seite 24 - “CPJ” and “CPJS” SERIES

9WELL TO PUMP CONNECTION (SUCTION PIPE)IL1392Glue33. The use of a union (optional) will assist with easy connection and disconnect. (Fig. 3)IL1346G

Kommentare zu diesen Handbüchern